Issue 6706 - printing high quality makes chart titles with "-" loose text after "-"
Summary: printing high quality makes chart titles with "-" loose text after "-"
Status: CLOSED FIXED
Alias: None
Product: printing
Classification: Unclassified
Component: www (show other issues)
Version: current
Hardware: PC Windows 98
: P3 Trivial
Target Milestone: OOo 1.1 Beta2
Assignee: oc
QA Contact: Unknown
URL:
Keywords:
: 6273 (view as issue list)
Depends on:
Blocks:
 
Reported: 2002-08-02 10:11 UTC by lars
Modified: 2003-04-01 12:35 UTC (History)
1 user (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments
Set Printer Zoom to 100% (Xerox) (8.18 KB, application/x-zip)
2003-03-10 17:30 UTC, bjoern.milcke
no flags Details

Note You need to log in before you can comment on or make changes to this issue.
Description lars 2002-08-02 10:11:20 UTC
it seems to always occur under the following circumstances:


close all OOo apps.

open a spreadsheet by double click on file


Use "print" (not "print directly") and select the highest print 
quality.

Charts within the current on screen displayed part "receive" this 
problem.


It does not occur with other print quality options.
It does not occur when the highest print quality option is already 
set for this document.

It does not occur anymore when chart has been entered and exited 
after printing made the error occur, so that text reappears.

It seems to be independant from the printer associated with the 
document in the document.
It seems to be independant from the screen resolution.

! Perhaps set the standard printer print quality option to lowest 
(control panel->printers-><your printer>->...) before opening the 
document.

It occurred on 2 inkjet printers: Lexmark Z32 and HP Deskjet 930C.


Test document attached. http://www.openoffice.org/issues/showattachment.cgi?
attach_id=2308&file=C:\Eigene Dateien\unzipped\Gamma-Spektroskopie.sxc


System: both Win98 SE german; AMD CPUs, OOo german 1.0.0
Comment 1 lars 2002-08-02 10:12:09 UTC
*** Issue 6273 has been marked as a duplicate of this issue. ***
Comment 2 lars 2002-08-17 18:39:50 UTC
no voting possible, hmm


Is this the right component?


Could everyone (yes; as it seems to be a bug on all Windows systems) 
try to reproduce it?
Comment 3 lars 2002-09-25 20:15:48 UTC
perhaps "reassignment issue" issue 7735 "occured"
Comment 4 philipp.lohmann 2002-11-12 13:24:43 UTC
pl->ssa: either a driver or chart "feature" ?
Comment 5 stephan_schaefer 2002-12-02 09:44:49 UTC
It seems that the application does not react on printer resolution
changes during printing. I saw this behaviour in swriter a while ago
and filed a bug to the writer team. But it seems, that other
applications ignore those changes too.
Comment 6 niklas.nebel 2003-02-14 18:08:52 UTC
The change that was done in Writer doesn't apply to Calc because we
don't store the layout.

Oliver, we've had similar problems with PDF export and with
transparent objects, but I can't reproduce this one. Can you take a look?
Comment 7 kla 2003-03-07 13:41:18 UTC
Hi Bjoern,
i can reproduce it.
As discussed for you.
Comment 8 bjoern.milcke 2003-03-07 14:38:44 UTC
Can also be reproduces on Linux by changing the scale of a PostScript
printer e.g. to 120%.
Comment 9 bjoern.milcke 2003-03-10 17:30:21 UTC
Created attachment 5042 [details]
Set Printer Zoom to 100% (Xerox)
Comment 10 bjoern.milcke 2003-03-11 10:41:42 UTC
Hi Niklas, I have changed sch/source/ui/docshell.cxx such that the
chart is re-rendered on printer change. However in this example, where
the printer does not change, but its settings, I get no
'OnDocumentPrinterChanged()' call. Please change this (In Draw and
Writer I get notified).
To test, load the attached document. It should suffice to just go to
the printer settings and change the zoom to 100% on the 'Advanced'
dialogue. (If you don't have this, try changing the DPI).
Note, that you may get a 'UserBreakpoint' in the debugger, while
changing the printer in the m5s2. You can go on 'continue'.
Comment 11 niklas.nebel 2003-03-11 18:15:59 UTC
Fixed in CWS calc05, will be in 1.1 Beta 2.
Changed files in Calc:
sc/source/ui/docshell/docsh3.cxx 1.15.4.1.14.1
sc/source/core/data/documen8.cxx 1.28.80.1
Comment 12 niklas.nebel 2003-03-17 09:14:25 UTC
Reassigning to QA for verification.
Comment 13 oc 2003-03-19 10:02:40 UTC
Reset resolution to fixed
Comment 14 oc 2003-03-19 10:03:05 UTC
Verified in internal build calc05
Comment 15 frank 2003-04-01 12:35:19 UTC
found integrated on Linux, Windows and Solaris using srx644m8s1